16.10 - Hardware - Data Stream Utility

Data Stream Utility Installation, Configuration, and Upgrade Guide for Customers

prodname
Data Stream Architecture
Data Stream Utility
vrm_release
16.10
created_date
August 2017
category
Configuration
Installation
featnum
B035-3153-087K

pNode/Server: For example, Dell PowerEdge R720xd, Dell PowerEdge R730xd, HP Gen9 or similar with the following minimum resources:

Item Resource
CPU 4
Memory 16 GB
Storage Datastore must be able to fit a 500 GB VMware image.

The OS drive uses approximately 200 GB of space and the DSU repository uses approximately 300 GB of space

Separate Physical Networks 1 – public

1 – DSU (10 GB network, optional)

Special Requirements

vCenter allows for distributed and local virtual switches. This version of vCenter only supports local virtual switches, so each ESXi host must have local virtual switches for the public network, and any optional CMIC or DSU networks.

The DSU virtual switches must have MTU values of 9000 for optimum performance.
  • For best performance, all virtual switches must be on their own physical network.
  • For low performance systems (for example, development or test), the virtual adapters can be placed on the same physical network, recognizing that performance is reduced with the shared bandwidth.

    With the exceptions of the public and CMIC subnets, using an MTU value of 9000 may cause problems on subnets that are using an MTU of a different size.

All virtual instances require static IPs.