ParallelUserServerAMPs

Purpose  

Specifies the maximum number of secure servers allowed to run simultaneously using the same operating system user ID on an AMP vproc.

Valid Range

1 through the value of SecureServerAMPs

Default

2

Usage Notes  

For example, a value of 2 allows two UDFs using identical operating system user IDs to run simultaneously. A third UDF would have to wait until one of the other UDFs finish.

Related Topics

For information on the maximum number of secure servers allowed to run simultaneously using the same operating system user ID on a PE vproc, see the UDF GDO field,“ParallelUserServerPEs” on page 127.