Connect - Call-Level Interface Version 2

Teradata Call-Level Interface Version 2 Reference for Workstation-Attached Systems

Product
Call-Level Interface Version 2
Release Number
15.00
Language
English (United States)
Last Update
2018-09-25
dita:id
B035-2418
lifecycle
previous
Product Category
Teradata Tools and Utilities

Connect

Purpose

Establishes a connection between an application and a specific COP server that is used for running Teradata SQL.

Usage Notes

The Connect parcel is sent from the client at the same time that a Logon parcel is sent.

This parcel is generated by CLIv2 on behalf of the application.

The response to a Connect parcel is first a Success parcel and then a RunResponse parcel.

Parcel Data

The following table lists field information for the Connect parcel.

 

Flavor Field

Body Parcel Length

Parcel Body Fields

88

24

 

PartitionName:

LogonSequence Number:

Function:

Pad:

16 bytes

4 bytes

2 bytes

2 bytes

Fields

  • PartitionName is the name of the COP server to which start requests are to be sent.
  • LogonSequenceNumber contains a logon sequence number when Function contains the value 2. At all other times it must contain zero.
  • Function contains one of the following:
  •  

    Function Number

    Description

    0

    Requests that a normal Run be performed.

    1

    Requests session control allocate a logon sequence number and associate the newly allocated logon sequence number with the requesting session.

    2

    Requests session control to associate the logon sequence number in logon sequence number with requesting session.

  • Pad is unused.