15.00 - UTY1625 Incompatible use of the FROM/FOR/THRU option with a previously specified CHECKPOINT parameter, terminating. - Teradata Tools and Utilities

FastExport, MultiLoad, and TPump (UTY Prefix) Messages

prodname
Teradata Tools and Utilities
vrm_release
15.00
category
Programming Reference
featnum
B035-1096-015K

UTY1625 Incompatible use of the FROM/FOR/THRU option with a previously specified CHECKPOINT parameter, terminating.

Explanation:

When using a FastLoad-compatible inmod, it is invalid to specify the FROM/FOR/THRU option if a CHECKPOINT parameter has been previously specified.

Generated By:

MLDSTMT

Remedy:

The FROM/FOR/THRU option on the IMPORT statement is incompatible with the CHECKPOINT parameter of the BEGIN MLOAD statement. Specify one or the other depending on the requirements of the application.