Concurrent Load Utility Tasks - FastLoad

Teradata FastLoad Reference

Product
FastLoad
Release Number
15.10
Language
English (United States)
Last Update
2018-10-07
dita:id
B035-2411
lifecycle
previous
Product Category
Teradata Tools and Utilities

Concurrent Load Utility Tasks

The maximum number of concurrent Teradata FastLoad tasks that can run is variable; the limit can be controlled by a system administrator. MaxLoadTasks may be overridden if Teradata Active System Management (Teradata ASM) is active.

For the most up‑to‑date information on concurrent task limits, see the description of the MaxLoadTask parameter of the DBSControl utility inUtilities (B035‑1102). Additional information is available in the Teradata Dynamic Workload Manager User Guide (B035‑2513).

If a Teradata FastLoad job exceeds recommended limits, Teradata FastLoad returns a 2633 error message indicating that too many loads are running. In this case, the utility retries until:

  • It can execute the task.
  • It reaches the TENACITY hours time limit specified by the BEGIN EXPORT command or runtime parameter.