Removing a Storage Drive - Data Warehouse Appliances

2750 Platform Hardware Replacement Guide for Customers

Product
Data Warehouse Appliances
Published
March 2018
Language
English (United States)
Last Update
2018-04-17
dita:mapPath
agq1471886743051.ditamap
dita:ditavalPath
2750.ditaval.ditaval
dita:id
yyc1471648425242
Product Category
Hardware
Removing a Storage Drive

  1. At the front of the cabinet, locate the drive enclosure with the amber Service Action Required LED.
  2. Locate the storage drive with amber Service Action Required and blue Service Action Allowed LEDs. The Service Action Allowed LED indicates that the module can be safely serviced.
  3. Press the latch release button, open the latch, and slide the drive out of the enclosure.
    After removing the failed storage drive, wait a minimum of 30 seconds before installing the new drive.
  4. Return to Server Management Client and, in the Replace FRU window, click Ok.