ALERT LIST TYPES - Teradata Unity

Teradata Unity User Guide

Product
Teradata Unity
Release Number
16.00
Published
March 2017
Language
English (United States)
Last Update
2018-03-29
dita:mapPath
ipb1476817227329.ditamap
dita:ditavalPath
ft:empty
dita:id
B035-2520
lifecycle
previous
Product Category
Analytical Ecosystem

Purpose

Lists all alerts and type IDs for ENABLE or DISABLE commands.

Syntax

ALERT LIST TYPES ;

Example

unityadmin>  ALERT LIST TYPES; 
----------------------------------------------
The following alerts are defined
Alert Type         : 1
Alert Description  : Unity sequencer has started
Alert Category     : System
Alert Severity     : Normal
Alert Status       : Enabled
Recommended Action : Normal system operation. Alert must be manually cleared.
----------------------------------------------
Alert Type         : 2
Alert Description  : An error has prevented a Unity process from starting. See log for details
Alert Category     : System
Alert Severity     : Critical
Alert Status       : Enabled
Recommended Action : Correct the error and try starting the process again.
----------------------------------------------
The output displays in this format.

Label

Description
Alert Type The alert number for this alert. Used when marking alerts as enabled or disabled.
Alert Description A general description.
Alert Category Which category/part of Unity the alert belongs to.
Alert Severity The severity of the alert (Normal, Warning, Critical).
Alert Status Enabled or disabled.
Recommended Action A default recommended action. This can be updated.