Work with Arrival Rate Meters | Teradata Vantage - 17.10 - Working with Arrival Rate Meters - Advanced SQL Engine - Teradata Workload Management

Teradata Vantage™ - Workload Management User Guide

Product
Advanced SQL Engine
Teradata Workload Management
Release Number
17.10
Release Date
July 2021
Content Type
Administration
User Guide
Publication ID
B035-1197-171K
Language
English (United States)

An ARM is a time-based flow rate rule. These are ARM rule attributes:

Attributes Description
Time Unit Time period for request rate (second, minute, hour).
Limit Maximum request rate per time unit (3 requests per minute).
Qualify Time Number of seconds that the current ARM rate must continuously remain at or above the limit before action is taken. A zero value means action is immediately taken as soon as the limit is reached.
Qualification Common classification criteria (Request Source, Query Characteristics, Target, and Query Band) can be specified to target specific types of requests (user, application, table scans, processing time, and so on).
Action Rule action performed when Limit and Qualify Time conditions are met. Actions include Delay, Reject, and Logging (warning mode).

Limit, Reject, and Delay action attributes are state-dependent values.

Logging (warning mode) is similar to that of Filters. See Warning Mode.

For more information, see Teradata Vantage™ - Application Programming Reference, B035-1090 and Teradata Viewpoint Workload Designer in Teradata® Viewpoint User Guide, B035-2206.