Explanation:

TDP is ending because the subsystem interface module (hsiossimodulename) is an incorrect version of TDP.

Generated By:

TDP.

Notes:

None.

Remedy:

Correct the error with method 1 or method 2: 1. Check for the correct module version with a different suffix character than used before. Include the correct INITIAL OSSISUFX command in the TDPPARM data set. Start TDP again. 2. Ensure that the correct module appears in the PLPA, MLPA, or FLPA. IPL MVS and start TDP again.