TDP1782 PARCEL (type) INCOMPLETE BY number BYTES IN CHECK-NEW RESPONSE - Teradata Tools and Utilities

Teradata Director Program (TDP Prefix) Messages

Product
Teradata Tools and Utilities
Release Number
15.xx,16.xx
Content Type
Messages
Publication ID
B035-1096-162K
ft:locale
en-US
ft:lastEdition
2018-10-23
ft:sourceId
FTML
dita:id
B035-1096-TDP
lifecycle
latest
Product Category
Teradata® Tools and Utilities

TDP1782 PARCEL (type) INCOMPLETE BY number BYTES IN CHECK-NEW RESPONSE

Explanation:

While recovering from loss of communication with a CP, a Session-Info Response from the Teradata Database contained a parcel of the type indicated that was too short by the indicated number of bytes.

Generated By:

TDP.

Notes:

The CP being used is halted and the request will be retried using another CP, if one is available.

Remedy:

Contact Customer Support personnel to report the erroneous Teradata Database response.