TDP2202 "cpname" IS WAITING FOR COMMUNICATION TO BE ESTABLISHED - Teradata Tools and Utilities

Teradata Director Program (TDP Prefix) Messages

Product
Teradata Tools and Utilities
Release Number
15.xx,16.xx
ft:locale
en-US
ft:lastEdition
2018-10-23
dita:id
B035-1096-TDP
lifecycle
latest
Product Category
Teradata® Tools and Utilities

TDP2202 "cpname" IS WAITING FOR COMMUNICATION TO BE ESTABLISHED

Explanation:

One or both devices for the CP are not responding. I/O will be retried every 30 seconds until communication is restored (the message appears only once for each loss of communication, not once for each retry).

Generated By:

TDP.

Notes:

This situation may arise either when the CP is STARTed or after a STARTed CP loses communication. The CP either remains in the STARTing state (if the CP has just been STARTed) or enters the SYNC'ING state (if communication has been lost).

Remedy:

If the Teradata Database is restarting, no action is required. Otherwise, the cause for the CP not communicating should be investigated.