TDP2201 additional information

Explanation:

If additional meaningful detail exists for an I/O error, this message follows a TDP2200 message. One or more of the following three pieces of information will be present: DEVSTAT(status) formats any nonzero device status as one or more of ATTN (Attention), SM (Status Modifier), CUE (Control-unit End), BUSY, CE (Channel End), DE (Device End), UC (Unit Check), and UEX (Unit Exception). SCHSTAT(status) formats any nonzero subchannel status as one or more of PCI (Program-controlled Interrupt), IL (Incorrect Length), PGMC (Program Check), PRTC (Protection Check), CDC (Channel-data Check), CCC (Channel-control Check), IFCC (Interface-control Check), and CC (Chainin Check). SENSE(data) displays the hexadecimal value for up to two bytes of sense data, if a Unit Check occurred and such data was provided.

Generated By:

TDP.

Notes:

A TDP2203 message will follow to indicate that the CP is no longer usable.

Remedy:

Contact Customer Support personnel and provid the text of the TDP2200 and any TDP2201 messages.