16.20 - Usage Notes - Teradata Vantage NewSQL Engine

Teradata Vantage™ SystemFE Macros

prodname
Teradata Database
Teradata Vantage NewSQL Engine
vrm_release
16.20
created_date
March 2019
category
Administration
featnum
B035-1103-162K

The MiniCylPacks report is based on event codes 034-05141-00, 034-05142-00, and 034-05143-00.

You can use the ListErrorCodes macro to get a brief description of these events. For a detailed description, see “Teradata Database Messages” in Teradata Vantage™ - Database Messages, B035-1096.

This macro is useful to determine whether MiniCylPacks were done successfully, and whether they were performed in anticipation of their use or while there were other tasks waiting. This information is determined based on the specific event code, as follows:

Event Code Description
5141 Indicates an anticipated, successful freeing of cylinders.
5142 Indicates a successful freeing of cylinders, but caused other tasks to wait.
5143 Indicates no success at freeing cylinders, and that the event caused other tasks to wait.
These event codes can also be viewed in the ListErrorCodes report (see “ListErrorCodes”).