TDP3980 NPNUM xxxx: status - Teradata Director Program

Teradata Director Program (TDP Prefix) Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
Lake
VMware
Product
Teradata Director Program
Release Number
15.xx, 16.xx, 17.xx, 20.xx
Published
June 2020
Language
English (United States)
Last Update
2023-11-20
lifecycle
Latest
Product Category
Teradata Tools and Utilities

TDP3980 NPNUM xxxx: status

Explanation:

In response to a TDP 'DISPLAY NP' command either when the DETAIL operand is specified, or when the status is not normal (not yet initialized, or quiesced), this message displays a Database network communication device processor number (if known, else zeroes), an indication if a Database NP has not yet been acquired, its communication status (OPERATIONAL or NOT OPERATIONAL), and its database status as one or more of the following: - INIT'ING ENVELOPE if the encapsulation protocol is being initialized. - INIT'ING PROTOCOL if the communication protocol is being initialized. - SYNC''ING if TDP and the Database are synchronizing their status. - QUIESCED if the number of requests requests sent without receiving any responses has exceeded the SET LIMIT NORESP value

Generated By:

TDP.