TDP3672 TRDTXNES: IN-USE BUT NOT CURRENT - Teradata Director Program

Teradata Director Program (TDP Prefix) Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
Lake
VMware
Product
Teradata Director Program
Release Number
15.xx, 16.xx, 17.xx, 20.xx
Published
June 2020
Language
English (United States)
Last Update
2023-11-20
lifecycle
Latest
Product Category
Teradata Tools and Utilities

TDP3672 TRDTXNES: IN-USE BUT NOT CURRENT

Explanation:

A TRDTXNES routine found an event was both in-use but not current. The leftmost byte of General register fifteen contains one of the following values: 1 for the Cleanup handler 2 for the Flush-I/O service routine 3 for the CommProb cleanup (UCCP) The rightmost byte contains one of the following values: 1 if for an event emptying a TCP buffer. 2 if for an event confirming receipt of data by the Database. 3 if for an event detected when scheduled.

Generated By:

TDP.

Notes:

This condition is indicated by an abnormal termination rather than a message. It indicates an internal error in TDP.

Remedy:

Collect diagnostic information (including the memory dump, if any) and contact Customer Support personnel.