Removing a Storage Drive - Integrated Big Data Platforms

1700 Platform Hardware Replacement Guide for Customers

Product
Integrated Big Data Platforms
Published
March 2018
Language
English (United States)
Last Update
2018-04-17
dita:mapPath
nzd1471887229846.ditamap
dita:ditavalPath
1700.ditaval.ditaval
dita:id
uan1471643170946
Product Category
Hardware
Removing a Storage Drive

  1. Press the release button to disengage the failed storage drive from the internal connector.
    Before fully removing the storage drive from the drive bay, wait a minimum of 60 seconds for the internal disks to stop spinning.
  2. Slide the storage drive out of the drive bay. Do not install the replacement drive yet. After removing the failed storage drive, wait 60 seconds until the software verifies the drive has been removed.
  3. Return to Server Management Client and, in the FRU Replace window, click Ok. The software checks that the storage drive has been removed.
    If an error message appears, click Cancel. Resolve the issue, then reinitiate the FRU replacement procedure. Contact Teradata Support for assistance.