Configuring Internal Storage for an HP System

Teradata Database on VMware Base, Advanced, Enterprise Tiers Getting Started Guide

brand
Cloud
prodname
Teradata Database on VMware
vrm_release
Deployer 3.01
category
Configuration
Installation
featnum
B035-5958-097K
  1. Before running the hp.storage.configuration.ps1 script which configures the internal storage, ensure the ProLiant DL380 Gen9 server is running firmware at the following minimum versions or later. See the documentation that is specific to your HP system if you need to upgrade to these versions.
    HPSSACLI SOULAPI PowerCLI 5.5
    2.20.11.0 8.2.11.0 Release 2 or later
  2. Run the hp.storage.configuration.ps1 script.
    The script may reboot the server that is being configured.
    The script creates RAID-1 logical drives on the HP internal storage and can also be used to print and validate the settings of the existing HP logical drives based on recommended settings.