Restarting After an Unrecoverable I/O Error - MultiLoad

Teradata® MultiLoad Reference

Product
MultiLoad
Release Number
16.20
Published
October 2018
Language
English (United States)
Last Update
2018-10-10
dita:mapPath
lsl1527114222348.ditamap
dita:ditavalPath
Audience_PDF_product_tpt_userguide_include.ditaval
dita:id
B035-2409
lifecycle
previous
Product Category
Teradata Tools and Utilities

The Teradata MultiLoad utility automatically attempts a restart operation after encountering an unrecoverable I/O error while accessing a fallback type table.

Status messages on screen 7 of the database operator’s console reflect the progress of the restart operation, and some I/O error conditions can force an AMP to become a nonparticipant in the Teradata MultiLoad job. In this case, the Teradata MultiLoad job is stopped with error messages such as:

AMP XXX-X Starting rebuild of db.tbl
AMP XXX-X AMP marked as non-participant for - db.tbl
AMP XXX-X Completed rebuild of table db.tbl

Additional error messages indicate errors that may occur during the restart operation.