STOP FORCE - IBM CICS Interface for Teradata

IBM CICS Interface for Teradata Reference

Product
IBM CICS Interface for Teradata
Release Number
15.10
Language
English (United States)
Last Update
2018-10-07
dita:id
B035-2448
lifecycle
previous
Product Category
Teradata Tools and Utilities

STOP FORCE initiates the following events:

1 The following message is displayed in response to STOP FORCE.

DCI0208 ENTRYNAME: tdpid STOP FORCE PROCEEDING
 

IF the option is initiated . . .

THEN . . .

from a terminal

DAFC next releases the terminal and attaches to a non-terminal related transaction to complete the stop force process.

implicitly

the stop force process completes.

2 Applications abend with an AEY9 abend code if they attempt to start a new logical unit of work.

3 A 10-second timer starts to allow for the completion of the last in-flight unit of work.

4 Task-related user exits disable.

5 Applications abend with an abend code of ASP7 when any transactions still in flight at this time reach syncpoint.

6 The following messages display, depending on whether there were in-flight units of work or not.

 

IF there were . . .

THEN this message displays on the operator console and is written to the Transient Data Queue CSMT . . .

no in-flight units of work at the completion of the stop force process

DCI0206 ENTRYNAME: tdpid, STATUS: STOPPED

in-flight units of work at the completion of the stop force process

DCI0206 ENTRYNAME: tdpid, STATUS: STOPPED, IN-FLIGHT LUW:nnn

7 An authorized terminal operator can verify the status of the connection using the DAFC STATUS option.