STOP FORCE initiates the following events:
1 The following message is displayed in response to STOP FORCE.
DCI0208 ENTRYNAME: tdpid STOP FORCE PROCEEDING
IF the option is initiated . . . |
THEN . . . |
from a terminal |
DAFC next releases the terminal and attaches to a non-terminal related transaction to complete the stop force process. |
implicitly |
the stop force process completes. |
2 Applications abend with an AEY9 abend code if they attempt to start a new logical unit of work.
3 A 10-second timer starts to allow for the completion of the last in-flight unit of work.
4 Task-related user exits disable.
5 Applications abend with an abend code of ASP7 when any transactions still in flight at this time reach syncpoint.
6 The following messages display, depending on whether there were in-flight units of work or not.
IF there were . . . |
THEN this message displays on the operator console and is written to the Transient Data Queue CSMT . . . |
no in-flight units of work at the completion of the stop force process |
DCI0206 ENTRYNAME: tdpid, STATUS: STOPPED
|
in-flight units of work at the completion of the stop force process |
DCI0206 ENTRYNAME: tdpid, STATUS: STOPPED, IN-FLIGHT LUW:nnn
|
7 An authorized terminal operator can verify the status of the connection using the DAFC STATUS option.