Installing a Power Supply/Cooling Module - Data Warehouse Appliances

2850 Platform Hardware Replacement Guide for Customers

Product
Data Warehouse Appliances
Published
February 2018
Language
English (United States)
Last Update
2018-04-17
dita:mapPath
cgi1471887107887.ditamap
dita:ditavalPath
2850.ditaval.ditaval
dita:id
drz1471648613954
Product Category
Hardware
Installing a Power Supply/Cooling Module

  1. Loosen the captive screw until the latch disengages from the new power supply/cooling module.
  2. Pull out the latch and insert the new power supply/cooling module into the open bay as far as it will go.
  3. Rotate the latch up until it engages the power supply/cooling module to the internal connector.
    The power supply/cooling module is properly engaged when it is flush with the other modules within the enclosure.
  4. Manually tighten the captive screw.
  5. Plug in the power cord.
  6. Press the power switch on the new power supply/cooling module to the On position.