Cable Markings and Identification - Aster Appliances

Aster Appliance 5 Platform Hardware Installation Guide

Product
Aster Appliances
Published
February 2018
Language
English (United States)
Last Update
2018-04-16
dita:mapPath
tax1471886074092.ditamap
dita:ditavalPath
aster5.ditaval.ditaval
dita:id
mlo1471650768316
lifecycle
previous
Product Category
Hardware

Cable markings are placed either directly on the cable or on labels at each end of the cable. The cable markings provide the following information:

Bundle Type Cable Label Markings Description
InfiniBand network switch for base/expansion cabinets
On InfiniBand network switch end:
  • Ⓦ Pz ⇨
  • ⇦ Ⓦ Sx Py
On node end:
  • Sx Py ⇨
  • ⇦ Ⓦ Pz

w = node or InfiniBand network switch chassis number

Sx = node adapter slot number

Py = node adapter port number

Pz = InfiniBand network switch port number

InfiniBand network for InfiniBand cabinet (108-port, 324-port, and switch)
On InfiniBand cabinet switch end:
  • V Ⓦ LBx - Py ⇨
  • ⇦ V Ⓦ Pz Py
On chassis end:
  • V Ⓦ Pz Py ⇨
  • ⇦ V Ⓦ LBx - Py

V = InfiniBand/Processing cabinet number

W = node or InfiniBand chassis number

LBx = InfiniBand leaf board number

Py = InfiniBand leaf board port number

Pz = InfiniBand network switch port number

Server management for base/expansion cabinets
On chassis and switch end:
  • P

= wildcard represents cable end that can attach to closest chassis within reach (no specific chassis number required)

ⓐ - attic number

P = InfiniBand network switch port number

To match cable label information to Server Management cabling chassis numbers, see Server Management Cabling for Aster Cabinets .

Server management for InfiniBand switch cabinet (108-port switch)
On chassis and switch end:
  • Ⓦ Px ⇨
  • ⇦ Ⓦ Px

w = chassis number

Px = connector port number

Server management for InfiniBand switch cabinet (324-port switch)
On chassis and switch end:
  • Ⓦ Px ⇨
  • ⇦ Ⓦ M1-MGT

w = chassis number

Px = connector port number

Power for InfiniBand switch cabinet (108-port switch)
On AC box end:
  • Ⓦ xxxy ⇨
  • ⇦ Ⓐ PSb
On chassis power inlet end:
  • Ⓐ PSb ⇨
  • ⇦ Ⓦ xxxy

W = Blue or Orange dot for AC box color

xxx = AC box row (TOP or BOT)

y = outlet (1, 2, 3, or 4)

A = chassis number

PSb = chassis power inlet (1, 2, 3, or 4)

Power for InfiniBand switch cabinet (324-port switch)
On AC box end:
  • Ⓦ xxxy ⇨
  • ⇦ Ⓐ ACb
On chassis power inlet end:
  • Ⓐ ACb ⇨
  • ⇦ Ⓦ xxxy

W = Blue or Orange dot for AC box color

xxx = AC box row (TOP or BOT)

y = outlet (1, 2, 3, or 4)