set_status_rate - BAR - Data Stream Architecture - Use the set_status_rate command to configure the status update rate between DSC and the media servers or Teradata systems. Learn more here.

Teradata® DSA User Guide

Product
BAR
Data Stream Architecture
Release Number
16.20
Published
November 2019
Language
English (United States)
Last Update
2019-11-27
dita:mapPath
xfr1514490991957.ditamap
dita:ditavalPath
3150_DSA_UG_1650-working-RR-new.ditaval
dita:id
B035-3150
lifecycle
previous
Product Category
Software
Teradata Tools and Utilities

Purpose

The set_status_rate command configures the status update rate between DSC and the media servers or Teradata systems.

Syntax

set_status_rate -n|-name Name -t|-type Type -r|-rate Rate

Example

dsc set_status_rate -n mediaserver1 -t system -r 15

Parameters

n|name Name
The name of the database system or media server name.
Example:  mediaserver1
t|type Type
The type of BAR components to update. Enter system or media_server.
Example:  SYSTEM
r|rate Rate
The rate of the status refresh in seconds. Default is 30 seconds. Valid range is between 30 and 60 seconds.
Example:  45
u|user_authentication User
Required when security management is enabled. Supplies the command with the Viewpoint user, and triggers a password prompt for authentication.

Permissions required: Administrator role

XML File Example

This command does not support an XML file.