- The Storage Firmware Download operation allows the downloading and updating of different types of firmware to various components of supported Teradata storage arrays in parallel.
- The Interconnect Firmware Download operation allows the downloading and/or updating of firmware for the Interconnect switch.
- A third option, Query Array Health, runs the Array Health Check for the selected arrays and displays the results at the end of the operation. If this option is selected, no actual firmware is downloaded.
Online Firmware Download is supported for NetApp Storage Arrays. Firmware is downloaded in groups to preserve AMP fallback. This means that storage arrays that have AMPs in the same cluster will not be downloaded to in parallel. One array must successfully complete firmware download before continuing to the subsequent array.
NetApp Arrays - All Arrays Except 280X and 5700 Controllers
- Teradata Storage Array controller firmware
- Teradata Storage Array NVSRAM
- ESM NVSRAM
- ESM Firmware
- Drive Firmware
For Drive Firmware, PUT allows one failure per drive group and does not terminate all downloads when a failure is encountered.
PUT downloads firmware to one component (controller, ESM card, or drive) per array at a time. For drive downloads, PUT downloads firmware to one drive from each drive group simultaneously, which increases parallelism to more than one drive per array. Once a download failure is encountered on an array, no other downloads are attempted on that array.
- Controller firmware (online and staged)
- ESM NVSRAM (online and staged)
- ESM
NetApp Arrays - 280X and 5700 Controllers
- Teradata Firmware Bundle: Downloads are supported online
- Teradata Storage Array NVSRAM: Downloads are supported online
- Drive Firmware: Downloaded to one drive at a time in the diskpool
For Drive Firmware, PUT allows one failure per drive group and does not terminate all downloads when a failure is encountered.
DotHill Arrays
- RAID Storage Firmware
- Drive Firmware
RAID Storage Firmware for DotHill arrays is delivered in a bundle and contains all components to be downloaded. It takes about 30 minutes per array for the RAID Storage System Firmware to download.
Drive firmware is updated in parallel across vdisks, one drive at a time, per vdisk. One exception: Arrays with controller firmware version CF101XXXX download sequentially, to one drive at a time.
Interconnect Switch
- Delete unused firmware image on a switch
- Reboot switch (only on 5030 switch)
- Copy and flash new firmware image to a switch
- Reboot switch