CLI0428 Maximum number of connections exceeded for user - Teradata Tools and Utilities

Mainframe Call-Level Interface (CLI Prefix) Messages

Product
Teradata Tools and Utilities
Release Number
15.xx,16.xx
Language
English (United States)
Last Update
2018-10-23
dita:id
B035-1096-CLI
lifecycle
latest
Product Category
Teradata® Tools and Utilities

CLI0428 Maximum number of connections exceeded for user

Explanation:

The user machine attempted to make more IUCV (Inter-User Communications Vehicle) connections than allowed according to the specification in the VM directory for the user machine. If no number is specified, four connections is the default.

Notes:

Each session that logs on to TDP is associated with an IUCV path (connection).

Remedy:

Contact your VM systems programmer and have the allowable number of IUCV connections increased by updating the VM directory appropriately. See the MAXCONN keyword on the OPTION directory statement.