The error messages shown in the following table correspond to Data Connector error codes that range from 0 to 999.
Error Code | Error Message Text | Description and Remedy |
---|---|---|
BAM0011 | Access Module called by < > when expecting < > | Teradata Extension for Tivoli Storage Manager is being called by a program other than ARCMAIN, but the extension can only be used for Teradata backup and restore. Remedy: Correct the software configuration and rerun the job. To determine the correct software version for the environment, refer to the release letter documentation or contact Teradata Customer Support. |
BAM0013 | Invalid open mode < > requested | Teradata Extension for Tivoli Storage Manager is being asked to open a file in an invalid mode. This error might indicate a software version incompatibility between Teradata Extension for Tivoli Storage Manager and the Data Connector. More likely, the error is related to some type of software corruption. Remedy: Contact Teradata Customer Support. |
BAM0018 | Expected Data Connector Version (< > < >) but actually got (< > < >) | The Data Connector version is incompatible with Teradata Extension for Tivoli Storage Manager. The Data Connector corresponds to the libpm.dll component on Windows and the libpm.so component on a UNIX system. Verify that the correct component is being loaded and the correct installation path is being used. Remedy: Correct the software configuration and rerun the job. To determine the correct software version for the environment, refer to the release letter documentation or contact Teradata Customer Support. |
BAM0020 |
|
The IOPARM string or the command contains a syntax error. This error message can result from a number of causes, all related to the user-entered command syntax. Remedy: Correct the error and resubmit the job. |
BAM0024 | Unsupported function code < > | Teradata Extension for Tivoli Storage Manager is incompatible with the calling program. The extension can only be used for Teradata backup and restore. Your version of ARCMAIN software might be incompatible with the Teradata Extension for Tivoli Storage Manager software. Remedy: Correct the software configuration and rerun the job. To determine the correct software version for the environment, refer to the release letter documentation or contact Teradata Customer Support. |
BAM0033 | < > Access Module currently does not support the < > file attribute < > Access Module currently does not support the < > function for < > file attribute |
Teradata Extension for Tivoli Storage Manager is incompatible with the calling program. Teradata Extension for Tivoli Storage Manager can only be used for Teradata backup and restore. This error suggests that a version of ARCMAIN software is being used that is not compatible with the extension’s software level. Remedy: Correct the software configuration and rerun the job. To determine the correct software version for the environment, refer to the release letter documentation or contact Teradata Customer Support. |