*** Failure 8205:LSN not found in the HUT controls segment.

The Failure 8205 message appears in the master stream (stream 1) ARC log because one or more child streams incurred a Teradata Database control error that aborted the ARC sessions. The ARC process of the master stream is notified by Teradata Database before the child stream can notify the master stream through the TARA server.