BYNET V5 Network Topology for Coexistence Systems - Active Enterprise Data Warehouse

6800 Platform Product and Site Preparation Guide

Product
Active Enterprise Data Warehouse
Published
February 2018
Language
English (United States)
Last Update
2018-04-19
dita:mapPath
vyt1471885165825.ditamap
dita:ditavalPath
6800.ditaval.ditaval
dita:id
jso1471649458844
Product Category
Hardware

The type and number of BYNET switch chassis and cabinets in a coexistence system are determined by system size. The table below shows the number of BYNET V5 switch chassis and cabinets needed, per node fabric. This is for BYNET 0 only. The configuration is repeated for BYNET 1.

System configurations larger than 324 nodes (to a maximum of 1,024 nodes) are accommodated by special order.
Number and Type of BYNET V5 Chassis and Cabinets in Coexistence Systems
Number of Nodes Number and Type of BYNET Switch Number of 9107 BYNET Cabinets (BYNET 0 Only)
1 - 18 One Mellanox 36-port InfiniBand switch, IS5030 or SX6036 0 - BYNET switch in base cabinet
19-108
  • One Mellanox InfiniBand SX6506-NR 108-port
  • One Mellanox InfiniBand GD4200 162-port
1
109 - 162
  • One Mellanox InfiniBand GD4200 162-port
  • One Mellanox InfiniBand SX6518 324-port
1
163 - 324 One Mellanox InfiniBand SX6518 324-port 1
325 - 648 One Mellanox InfiniBand SX6536 648-port 1