Verify Failover Configuration | Teradata Data Mover - 17.05 - Example: Verifying the Failover Configuration - Teradata Data Mover

Teradata® Data Mover Installation, Configuration, and Upgrade Guide for Customers

prodname
Teradata Data Mover
vrm_release
17.05
created_date
October 2020
category
Administration
Configuration
Installation
featnum
B035-4102-090K
  1. On DM1, run datamove list_agents and verify that all three Data Mover agents (DM1, DM2, and DM3) are running.
  2. On DM2, run /etc/init.d/dmdaemon status and verify that the output indicates NOT RUNNING.
  3. On DM2, run /etc/init.d/tdmrest status and verify that the output is NOT RUNNING.
  4. On DM2, run /etc/init.d/tdactivemq status and verify that the output status is NOT RUNNING.
  5. Run a Data Mover TPT job.
    1. Set max_agents_per_task to the number of Data Mover agents in the cluster.
    2. Set data_streams to a value greater than or equal to max_agents_per_task.
    3. Check the job status to verify that the job ran successfully and that all Data Mover agents are in use.