For CPs That Do Not Require the CCU Operand in the START Command
The following table provides the format and content of the EREP record for devices of a CP that do not require the CCU operand on the START command:
Byte # (Dec) |
Content Description |
0 |
Class/Source of record |
1 |
System/Release level |
2 — 5 |
Record switches (not used) |
6 |
Not used |
7 |
Reserved |
8 — 11 |
System date |
12 — 15 |
System time |
16 |
Machine version code |
17 — 19 |
CPU serial number |
20 & 21 |
CPU model (for example, 3033) |
22 & 23 |
Not used |
24 — 31 |
TDPid |
32 — 39 |
Failing CCW |
40 — 47 |
Content of CSW after I/O error |
48 |
Count of double words that record uses for device‑dependent data |
49 — 51 |
Secondary control unit address associated with final retry of failing I/O device |
52 — 55 |
Device type associated with failing device |
57 — 59 |
Primary control unit address of device being used when failure occurred |
60 & 61 |
Retry count |
62 & 63 |
Number of bytes of sense data (24) |
64 — 87 |
Sense data |
88 & 89 |
Not used |