For CPs That Do Not Require the CCU Operand in the START Command - Teradata Director Program

Teradata Director Program Reference

Product
Teradata Director Program
Release Number
15.00
Language
English (United States)
Last Update
2018-09-28
dita:id
B035-2416
lifecycle
previous
Product Category
Teradata Tools and Utilities

For CPs That Do Not Require the CCU Operand in the START Command

The following table provides the format and content of the EREP record for devices of a CP that do not require the CCU operand on the START command:

 

Byte # (Dec)

Content Description

0

Class/Source of record

1

System/Release level

2 — 5

Record switches (not used)

6

Not used

7

Reserved

8 — 11

System date

12 — 15

System time

16

Machine version code

17 — 19

CPU serial number

20 & 21

CPU model (for example, 3033)

22 & 23

Not used

24 — 31

TDPid

32 — 39

Failing CCW

40 — 47

Content of CSW after I/O error

48

Count of double words that record uses for device‑dependent data

49 — 51

Secondary control unit address associated with final retry of failing I/O device

52 — 55

Device type associated with failing device

57 — 59

Primary control unit address of device being used when failure occurred

60 & 61

Retry count

62 & 63

Number of bytes of sense data (24)

64 — 87

Sense data

88 & 89

Not used