The following table lists the Teradata ARC return codes, their descriptions, and the recommended solution for each.
Return Code | Description | Recommended Action |
---|---|---|
0 | A normal termination of the utility. | |
4 | At least one warning message is in the output listing. | Review the output to determine which warnings and possible consequences are printed. |
8 | At least one nonfatal error message is in the output listing. A nonfatal error normally indicates that a request could not be met. A nonfatal error does not adversely affect other requests nor does it terminate task execution. |
Review the output to determine which errors are listed, and then deal with each error accordingly. |
12 | A fatal error message is in the output listing. A fatal error terminates execution. Restarting the task might be possible. |
Review the output to determine which error occurred and its cause. |
16 | An internal software error message is in the output listing. An internal error terminates execution. |
Gather as much information as possible (including the output listing), and contact Teradata customer support. |