Verifying Failover Configuration - Teradata Data Mover
Teradata Data Mover Installation, Configuration, and Upgrade Guide for Customers
- Product
- Teradata Data Mover
- Release Number
- 16.10
- Published
- June 2017
- Language
- English (United States)
- Last Update
- 2018-03-29
- dita:mapPath
- wcu1482331938115.ditamap
- dita:ditavalPath
- 4102_ICUCustomer_dm_1610.ditaval
- dita:id
- B035-4102
- Product Category
- Analytical Ecosystem
-
Verify that all Data Mover agents are listed in the output on the original-master:
datamove list_agents
-
Verify that the output is the same as in Step 1 on the designated-slave:
datamove list_agents
-
Verify the daemon is not active on the designated-slave:
/etc/init.d/dmdaemon status
-
Run a Data Mover ARC job.
-
Set max_agents_per_task to the number of Data Mover agents in the cluster.
-
Set data_streams to a value greater than or equal to max_agents_per_task.
-
Check the job status to verify that the job ran successfully and that all Data Mover agents are utilized.
-
Run a Data Mover TPT job.
-
Set max_agents_per_task to the number of Data Mover agents in the cluster.
-
Set data_streams to a value greater than or equal to max_agents_per_task.
-
Check the job status to verify that the job ran successfully and that all Data Mover agents are in use.