Verifying Failover Configuration - Teradata Data Mover

Teradata Data Mover Installation, Configuration, and Upgrade Guide for Customers

Product
Teradata Data Mover
Release Number
16.10
Published
June 2017
Language
English (United States)
Last Update
2018-03-29
dita:mapPath
wcu1482331938115.ditamap
dita:ditavalPath
4102_ICUCustomer_dm_1610.ditaval
dita:id
B035-4102
Product Category
Analytical Ecosystem
  1. Verify that all Data Mover agents are listed in the output on the original-master: datamove list_agents
  2. Verify that the output is the same as in Step 1 on the designated-slave: datamove list_agents
  3. Verify the daemon is not active on the designated-slave: /etc/init.d/dmdaemon status
  4. Run a Data Mover ARC job.
    1. Set max_agents_per_task to the number of Data Mover agents in the cluster.
    2. Set data_streams to a value greater than or equal to max_agents_per_task.
    3. Check the job status to verify that the job ran successfully and that all Data Mover agents are utilized.
  5. Run a Data Mover TPT job.
    1. Set max_agents_per_task to the number of Data Mover agents in the cluster.
    2. Set data_streams to a value greater than or equal to max_agents_per_task.
    3. Check the job status to verify that the job ran successfully and that all Data Mover agents are in use.