BAM1009 - NetBackup

Teradata Extension for NetBackup Administrator Guide

Product
NetBackup
Release Number
16.20
16.10
Published
May 2017
Language
English (United States)
Last Update
2018-05-02
dita:mapPath
bby1489436039204.ditamap
dita:ditavalPath
Audience_PDF_include.ditaval
dita:id
B035-2400
Product Category
Teradata Tools and Utilities

Access Module currently does not support repositioning when writing to backup files.

Explanation: The access module currently does not support restart processing when the backup file is opened in WRITE mode. This is because it is not possible to reposition to the exact point of failure inside the storage manager.
For whom: End User
Notes: All data written to the storage manager up to this point should be rolled back and deleted as a result of this error.
Remedy: At the current time, there is nothing the user can do other than to resubmit the job from the beginning of the current ARCMAIN step. If the user prefers to **NOT** resubmit the job at this time, they will probably want to issue a RELEASE LOCK statement on the Teradata server to remove any database locks set.