17.00 - 17 Buffer overflow - Teradata Tools and Utilities

DataConnector Messages

prodname
Teradata Tools and Utilities
vrm_release
17.00
created_date
June 2020
category
Programming Reference
featnum
B035-1096-DATACONNECTOR

17 Buffer overflow

Explanation:

The capacity of the DataConnector s buffers has been exceeded. This problem can be caused in several ways: 1) While reading text formatted data, a valid EOR byte was not found within the defined maximum record size. 2) While reading unformatted data, a record length less zero or greater than the maximum record size was requested by the utility. 3) While reading FastLoad formatted data, a record length greater than the maximum record size was encountered. 4) While writing, a record length greater than the maximum record size was provided by the utility.

Remedy:

Refer problem to access module support. If using Teradata Warehouse Builder, confirm that DataConnector Operator attribute "BufferSize" is not being exceeded.