CLI0531 Maximum Message Length exceeded - Mainframe Call-Level Interface

Mainframe Call-Level Interface (CLI Prefix) Messages

Deployment
VantageCloud
VantageCore
Edition
Enterprise
IntelliFlex
Lake
VMware
Product
Mainframe Call-Level Interface
Release Number
15.xx, 16.xx, 17.xx, 20.xx
Published
June 2020
Language
English (United States)
Last Update
2023-11-20
lifecycle
Latest
Product Category
Teradata Tools and Utilities

CLI0531 Maximum Message Length exceeded

Explanation:

The Message Length specified by the application is greater than the maximum allowable of 32K-1.

Notes:

This error is detected by the TDP, not CLI. The Teradata Database allowable maximum is less than 32K-1 (32K-32 as of release 4.0), and if exceeded will give its own error code. This condition is no longer produced by TDP. The description remains in case a downlevel version of TDP is being used.

Remedy:

Shorten the message.