The following properties are configurable for the emmonitorrest service in /etc/opt/teradata/em/emmonitorrest.conf:
Property Description Default value
CPUInterval Data collection frequency interval in seconds for metrics in metricGroup CPU 30
MemoryInterval Data collection frequency interval in seconds for metrics in metricGroup Memory 30
DiskInterval Data collection frequency interval in seconds for metrics in metricGroup Disk/IO 30
NetworkInterval Data collection frequency interval in seconds for metrics in metricGroup Network 30
TomcatPort Port that tomcat is using for listening 8090
H2AdminUserName Admin user name to connect to H2 admin
H2AdminPassword Password to admin user to connect to H2 teradata
H2RestUserName User name the emmonitorrest client provides while making a REST call emem
H2RestPassword Password to H2RestUserName em
H2TCPPort H2 TCP port 9092
DaysToHoldData Maximum number of days the monitored data stays persisted 5
A change in value for CPUInterval, MemoryInterval, DiskInterval and NetworkInterval does not require emmonitorrest service restart. The service needs to be restarted for changes in any of the other properties.
The minimum data collection frequency interval is 30 seconds. If you modify the interval to less than 30, the previous value returns.