Job streams stall in a connecting state when the ABU server and ABU client are unable to connect to each other.
  1. If the streams for one node are stalled in the connecting state, restart the ABU client service on that node by typing /etc/init.d/tdabuclient restart.
  2. If the streams for all nodes are stalled in the connecting state, restart the ABU server by typing /etc/init.d/tdabusrv restart. ABU clients restart automatically, within five minutes of the ABU server restart.