By default, the Aster Informatica Connector treats numeric datatypes as doubles. As a result, any numeric value with a precision exceeding 15 digits will not be properly transferred. To load or export numeric values with precisions greater than 15 digits, use this procedure.
  1. In the PowerCenter Workflow Manager, go to the Task Developer tool.
  2. Right-click the task and select Edit.
  3. Select the Properties tab.
  4. Make sure the property Enable High Precision is checked.