System Event Type Options (TASM)

Teradata Viewpoint User Guide

brand
Analytical Ecosystem
prodname
Teradata Viewpoint
vrm_release
16.00
category
User Guide
featnum
B035-2206-106K
System event type options are available in the following versions of Teradata Database.
Event Types Description 14.0 and later 13.10
Node Down Maximum allowed number of nodes down in a clique, defined as a percentage between 0 and 100. The default is 24%. Available Available
AMP Fatal Maximum number of AMPs reported as fatal at system startup. Available Available
Available AWTs Number of AWTs available on the specified number of AMPs as defined in the Other tab of the General view. Includes a qualification time. Available Available
Gateway Fatal Maximum number of gateways reported as fatal at system startup. Available Available
PE Fatal Maximum number of PEs reported as fatal at system startup. Available Available
Flow Control Maximum allowed number of AMPs in flow control. Includes a qualification time. Available Available
CPU Utilization Defines when the system CPU values are consistently outside defined CPU utilization threshold values. Includes a qualification time. Available  
CPU Skew Maximum system-wide skew. Includes a qualification time. Available  
Setting qualification times can prevent very short incidents from triggering events.
Qualification Time Options Description
Simple

Specifies how long an event threshold must be met before an event is triggered.

Immediate

Specifies that an event is triggered immediately after an event threshold is met.

Averaging

Specifies how long the rolling average of the metric value must meet the event threshold before an event is triggered.