Check Dispatcher HA | Teradata Unity - Checking Dispatcher HA - Continuous Availability - Teradata Unity

Teradata® Unity™ Monitoring and Management Guide

Product
Continuous Availability
Teradata Unity
Release Number
17.00
Published
September 2020
Language
English (United States)
Last Update
2020-09-15
dita:mapPath
yuc1569253595897.ditamap
dita:ditavalPath
ft:empty
dita:id
yuc1569253595897
Product Category
Analytical Ecosystem
If the Unity system is undergoing planned maintenance, wait until the maintenance window is complete before checking managed system health.
If the Unity system mode is standalone or dual standalone, do not check Dispatcher HA status.
  1. At unityadmin, run the following command:
    DISPATCHER STATUS;
  2. Confirm the following dispatcher results:
    • System Connectivity: Process is UP (active), Connected to a system
    • System Connectivity: Process is UP (standby), Connected to a system