Error Table

Each error table row can include up to ten columns of information that you can use to help determine the cause of the error. You can specify any or all of these columns, in any order, in the SELECT statement used to access the error table.

The following table lists the Stream error table columns that can be specified.

 

Table 10: Error Table Columns 

Column.

Contents

DataSeq

Sequence number assigned to the input source in which the error occurred.

DMLSeq

Sequence number assigned to the DML group in which the error occurred.

ErrorCode

Code for the error.

ErrorField

This field is zero for the Stream operator.

ErrorMsg

The Teradata Database error message for the error.

HostData

Client data being processed when the error occurred.

LoadStartTime

Queue Insertion TimeStamp (QITS) value indicates when the job started. On restart, it indicates when the job restarted.

RowInsertTime

Indicates when the row was inserted into the Stream operator error table.

SourceSeq

Sequence number assigned to the row from the input source (the DataSeq number) in which the error occurred.

STMTSeq