DCI0205 xxxx IS NOT DEFINED IN THE DBCDLT

Explanation:

DAFC was invoked to start or stop the connection to TDPid xxxx. The function can not be performed because TDPid xxxx is not defined in the DBCDLT, the DBC List Table.

Remedy:

If an incorrect TDP has been specified, correct and reissue the command. Otherwise contact Customer Support personnel to determine the reason that the specified TDP has not been pre-defined in the DBCDLT.

Notes:

Each TDPid with which applications may establish two-phase commit mode sessions must be pre-defined in the DBCDLT. This is verified during attempts to start or stop the connection.