17.00 - DII0000 IMS direction REQUEST IS INCONSISTENT WITH tdpid MANUAL RESOLUTION - Teradata Tools and Utilities

CICS Interface (DCI Prefix) Messages

prodname
IBM CICS Interface for Teradata
Teradata Tools and Utilities
vrm_release
17.00
created_date
June 2020
category
Programming Reference
featnum
B035-1096-CICS

DII0000 IMS direction REQUEST IS INCONSISTENT WITH tdpid MANUAL RESOLUTION

Explanation:

Automatic in-doubt resolution was requested to perform the indicated action (either "COMMIT" or "ABORT"), but the transaction has already been manually resolved in the indicated Teradata Database in the opposite way.

Notes:

A DII0100 message will follow to indicate the recovery unit that could not be resolved.

Remedy:

Evaluation and removal of any effects of the inconsistency among all involved databases must be performed.