Purpose  

The TENACITY command specifies the number of hours that Teradata FastLoad continues trying to log on when the maximum number of load operations is already running on the Teradata Database.

Syntax  

where

 

Syntax Element

Description

hours

Number of hours that Teradata FastLoad continues trying to log on.

The hours specification must be greater than zero. If zero is entered, Teradata FastLoad responds with an error message and terminates.

Usage Notes  

Table 52 describes the things to consider when using the TENACITY command.

 

Table 52: Usage Notes for TENACITY 

Topic

Usage Notes

Function

The TENACITY specification works with the SLEEP specification to control Teradata FastLoad logon attempts.

When Teradata FastLoad tries to log on for a new session, and the Teradata Database indicates that the maximum number of load sessions is already running, Teradata FastLoad:

1 Logs off any new sessions that were logged on

2 Waits for 6 minutes, by default, or for the amount of time specified by the SLEEP command

3 Tries again to log on to the Teradata Database

Teradata FastLoad repeats this process until it has either logged on for the required number of sessions or exceeded the amount of time specified by the TENACITY command.

For more information on how the TENACITY command interacts with the SLEEP command, please see Table 51 on page 165.

Note: The utility default for TENACITY is no tenacity. A Teradata FastLoad configuration file entry, the runtime parameter, or a TENACITY command must be used in the Teradata FastLoad job script to enable the tenacity feature for the Teradata FastLoad logon operation.

Command Placement

Command placement affects the logon operation. State the TENACITY and SLEEP commands before the LOGON command in the Teradata FastLoad job script. Teradata FastLoad terminates with an error message if the Teradata FastLoad job script states the TENACITY or SLEEP command after the LOGON command.

Command Overrides

The TENACITY and SLEEP command specifications override the corresponding TENACITY and SLEEP specifications that may be made in the Teradata FastLoad configuration file.

Similarly, the TENACITY and SLEEP command specifications themselves are overridden by the corresponding specifications made as runtime parameters when invoking Teradata FastLoad.

The order of preferences for the TENACITY and SLEEP specifications, from highest to lowest, is:

1 Runtime parameters

2 Teradata FastLoad script commands

3 Teradata FastLoad configuration file specifications

4 Teradata FastLoad default values