Coexistence Rules for TVS Storage Mode - Active Enterprise Data Warehouse

6700 Platform Product and Site Preparation Guide

Product
Active Enterprise Data Warehouse
Published
March 2018
Language
English (United States)
Last Update
2018-04-18
dita:mapPath
npo1471884913832.ditamap
dita:ditavalPath
6700.ditaval.ditaval
dita:id
gka1471649157954
Product Category
Hardware
Component Rules
Generation

Nodes in coexistence systems must follow coexistence rules for their generation. Each generation must have certified storage for the platform to which it is attached.

Arrays

All 6700C storage drives must be HDD storage drives.

All 6700H and 6700X storage drives must be hybrid HDD and SSD storage drives.

Contact GSS for clique configurations for coexistence systems.

Drives of different capacities can be mixed within a tray.

When mixing drives in an array, RAID pairs/sets should be the same capacity drives. If you mix two different capacities in a RAID pair, PUT treats the larger drive like the smaller drive and you lose the extra capacity.

You cannot mix more than two drive capacities in an array.

RAID You cannot mix RAID types.
Design

Mixed storage design must be matched to data temperature demographics.

Teradata

All 6843 array models can be mixed in the clique.

All 6844 array models can be mixed in the clique.