TDP3619 "npname" INELIGIBLE FOR ACQUISITION, REASON: "text" - Teradata Tools and Utilities

Teradata Director Program (TDP Prefix) Messages

Product
Teradata Tools and Utilities
Release Number
15.xx,16.xx
Language
English (United States)
Last Update
2018-10-23
dita:id
B035-1096-TDP
lifecycle
latest
Product Category
Teradata® Tools and Utilities

TDP3619 "npname" INELIGIBLE FOR ACQUISITION, REASON: "text"

Explanation:

When STARTing an NP after specifying a TDP command CONFIG NP DATABASE value, an NP could not be acquired. The DETAIL operand was specified on the START command, and this is the first of four messages that provide detail about the problem. The reason that the acquisition failed is given as one of the following: 'UNKNOWN IP NAME' if the name was not known to the network. 'NUMERIC IP ADDRESS IN USE' if the numeric IP address corresponding to the name is in use by another NP for this TDP. 'NUMERIC IP ADDRESS UNAVAILABLE' if the numeric IP address corresponding to the name could not be obtained. '(UNKNOWN REASON)' if the reason was not valid.

Generated By:

TDP.

Notes:

None

Remedy:

This message provides diagnostic information and does not indicate another error, unless '(UNKNOWN REASON)' appeared.