TDP0160 TDPNSPCI INCOMPATIBLE WITH HSISXMS - Teradata Tools and Utilities

Teradata Director Program (TDP Prefix) Messages

Product
Teradata Tools and Utilities
Release Number
15.xx,16.xx
Language
English (United States)
Last Update
2018-10-23
dita:id
B035-1096-TDP
lifecycle
latest
Product Category
Teradata® Tools and Utilities

TDP0160 TDPNSPCI INCOMPATIBLE WITH HSISXMS

Explanation:

TDP is ending because the subsystem interface modules (TDPNSPCI and HSISXMS) are at incompatible levels.

Generated By:

TDP.

Notes:

None.

Remedy:

Correct the error with method 1 or method 2: 1. Check for the correct module versions with a different suffix character than used before. Include the correct INITIAL PCSUFX/OSSISUFX command in the TDPPARM data set. Start TDP again. 2. Ensure that the correct modules appear in the PLPA, MLPA, or FLPA. If not, reload the correct modules and re-start TDP.