UTY6656 Explicit positioning with overlappings are not allowed after variable length field with FORMAT UNFORMAT.

Explanation:

With format unformat data, if explicit positioning is used with overlappings after the first variable-length field, then TPump will terminate.

Generated By:

TLDPREP

Remedy:

Either remove the explicit positioning fields that overlap which are located after the first variable length field, or change the input data format to either FASTLOAD or BINARY. Then resubmit the program.