16.10 - Setting Intel e1000 Network Ports for 1GbE Adapters - Data Stream Utility

Data Stream Utility Installation, Configuration, and Upgrade Guide for Customers

prodname
Data Stream Architecture
Data Stream Utility
vrm_release
16.10
created_date
August 2017
category
Configuration
Installation
featnum
B035-3153-087K

The following settings are to be configured only for 1 GbE Intel ports with an e1000 driver.

  1. Edit the BAR data network adapter file /etc/modprobe.conf.local on each BAR server:
    #
    options e1000 \
    TxDescriptors=4096,4096,4096,4096,4096,4096,4096,4096, 4096,4096,4096,4096 \
    RxDescriptors=4096,4096,4096,4096,4096,4096,4096,4096, 4096,4096,4096,4096 \
    InterruptThrottleRate=0,0,0,0,0,0,0,0,0,0,0,0 \
    RxIntDelay=0,0,0,0,0,0,0,0,0,0,0,0 \
    RxAbsIntDelay=0,0,0,0,0,0,0,0,0,0,0,0 \
    TxIntDelay=0,0,0,0,0,0,0,0,0,0,0,0 \
    TxAbsIntDelay=0,0,0,0,0,0,0,0,0,0,0,0
    #
  2. Save the changes and exit the file.
    Reboot the BAR server for the settings to take effect.