This procedure assumes you have obtained or verified the primary MAC address and secondary MAC address (if applicable) of the chassis you are adding to the CMIC configuration.
- Access the web page of the managing CMIC.
- From the web page of the managing CMIC, select .The CMIC configuration of the managing CMIC opens in the CMIC Configuration Editor.
- Locate the entry for the chassis.
- If the entry is a Data Domain 6800 or 9300 Storage System, update the entry.The entry should look similar to the following:
<Chassis idnum="### INSERT CHASSIS NUMBER ###"> <MEPlugin name="MEPlugin_Disk_Array_DDxxxx"/> <NetAdapter mac="### INSERT MAC ###"> <IPv4 addr="0.0.0.0" netmask="0.0.0.0" type="### INSERT NETWORK TYPE ###"/> </NetAdapter> </Chassis>
- Update the IPv4 network type, address, and netmask.
- Edit the CMIC configuration with public access to include fwzone="barmonitored":
<NetAdapter fwzone="barmonitored" mac="xxxxxxxxxxxx"> <IPv4 addr="153.64.xxx.xxx" gateway="153.64.xxx.xxx" netmask="255.255.xxx.xxx" type="153.64.xxx.xxx/23"/> </NetAdapter>
- Update the <IPv4 addr="xxx.xx.xxx.xx"> with the customer's public network address.
If this is a staged CMIC 11,type="public"
is correct; if this is an upgrade from CMIC 10 to CMIC 11, use the IP Address Configuration to determine the type.If the Data Domain 6800 and 9300 is on a public network, the completed CMIC configuration will look similar to the following (this example includes a Data Domain 6800):<Chassis idnum="10" type="cmic"> <MEPlugin name="MEPlugin_CMIC_Alcolu" <NetAdapter mac="000423DF0522"> <IPv4 addr="39.80.16.6" netmask="255.240.0.0" type="primary"/> <IPv4 addr="39.112.16.58" netmask="255.240.0.0" type="bmc1"/> </NetAdapter> <NetAdapter mac="000423DF0523"> <IPv4 addr="39.96.16.6" netmask="255.240.0.0" type="secondary"/> </NetAdapter> <NetAdapter fwzone="barmonitored" mac="000423E7C0D4"> <IPv4 addr="153.64.104.180" gateway="153.64.105.254" netmask="255.255.254.0" netname="smtest" type="153.64.104.0/23"/> </NetAdapter> </Chassis> <Chassis idnum="20"> <MEPlugin name="MEPlugin_Disk_Array_DD680000"/> <NetAdapter mac="00601649F5C4"> <IPv4 addr="153.64.207.14" netmask="255.255.254.0" type="153.64.207.0/23"/> </NetAdapter> </Chassis>
- To validate the syntax, click then OK.
- To transfer (put) the CMIC configuration to the managing CMIC, click then OK.
- To save the CMIC configuration to a backup location, navigate to the directory you want to use, click then Save.Use a backup location that is not on the server you are logged into.
The file is saved to the directory using the default file name and format, which is CMICConfig_SystemID_CollectiveID_CabinetID_CMICChassisID.xml. For example, CMICConfig_1_90_1_6.xml.
- Assign an IP address to the new chassis.