For CPs That Do Not Require the CCU Operand in the START Command - Director Program

Teradata Director Program Reference

Product
Director Program
Release Number
15.10
Language
English (United States)
Last Update
2018-10-07
dita:id
B035-2416
lifecycle
previous
Product Category
Teradata Tools and Utilities

The following table provides the format and content of the EREP record for devices of a CP that do not require the CCU operand on the START command:

 

Byte # (Dec)

Content Description

0

Class/Source of record

1

System/Release level

2 — 5

Record switches (not used)

6

Not used

7

Reserved

8 — 11

System date

12 — 15

System time

16

Machine version code

17 — 19

CPU serial number

20 & 21

CPU model (for example, 3033)

22 & 23

Not used

24 — 31

TDPid

32 — 39

Failing CCW

40 — 47

Content of CSW after I/O error

48

Count of double words that record uses for device‑dependent data

49 — 51

Secondary control unit address associated with final retry of failing I/O device

52 — 55

Device type associated with failing device

57 — 59

Primary control unit address of device being used when failure occurred

60 & 61

Retry count

62 & 63

Number of bytes of sense data (24)

64 — 87

Sense data

88 & 89

Not used